Structure 360
Triple Row Eurorack Road Case
Order Now

 

Level Up

Level up to a huge case to house a monster synth. The Structure 360 is a triple Row, 360hp eurorack travel case with detachable lid. The case includes a heavy duty, industrial strength power supply designed to exceed the needs of the most demanding analog and digital eurorack systems.

 

Structure 360 Power

  • 5 Amps of Clean, Filtered +12v Power

  • 5 Amps of Clean, Filtered -12v Power

  • 5 Amps of Clean, Filtered +5v Power

  • Case Wide 2 Channel Eurorack System Bus

  • 60 Keyed 16 Pin Eurorack Power Headers

  • External Power Switch with LED

  • Fused Power Protection

  • Universal IEC Power Connector

  • Discrete EMI filter per power rail (+12v, +5v, -12v)

  • Low Output Ripple & Noise

  • UL & CE Approved, ROHS Compliant

  • Over Load and Short Circuit Protection

  • Line Regulation (Full Load): ≤0.5%

  • Output Over Load Protection: 10%-150% Hiccup Mode with Auto-Recovery

 

Structure 360 Enclosure

  • Hardwood and Aluminum Construction

  • Three 120hp Rows

  • 360hp Total Space Available

  • Removable Lid

  • Lid Fits Over Fully Patched System (No need to remove patch cables)

  • Edge to Edge Rails Reduce Gaps Between Modules and the Side of the Case

  • 24 Smooth Sliding Square Nuts Per Rail Ensures Modules Always Fit Perfectly (Holds up to 72 modules)

  • Includes 150 Black (Size 4-40 1/4") Module Mounting Screws

  • Beautifully Hand-Stained Cabinet Grade Hardwood

  • Matching Black Steel Hardware Set

Structure 360 Dimensions

  • External Case Depth with lid: 9 1/4”

  • External Case Depth without Lid: 5 1/2”

  • External Case Height: 17”

  • External Case Width: 25 1/2”

  • Internal Base Depth Above Power Supply: 2 3/4”

  • Internal Base Depth Above Bus Board: 3 3/4”

  • Internal Base Depth Above Nothing: 4 1/4”

  • Internal Lid Depth: 2 3/4"

  • Empty Weight: 27 lbs


Installing Modules

Installing modules into a Pittsburgh Modular Structure case is easy. Click on the installation guide below for a simple walkthrough of the 5 step process.

WARNING! ALWAYS TURN OFF AND UNPLUG THE CASE BEFORE ADDING OR REMOVING MODULES. Incorrectly installed modules can cause damage to the case and other modules. Double check the orientation of the power ribbon cable before plugging in and turning on the case. 

WARNING! ALWAYS FILL UNUSED PANEL SPACE WITH BLANK PANELS. Stray patch cables touching the power headers can cause damage to the case and modules. Always cover empty rack spaces with blank panels.

WARNING! Not all modules will fit snug against the left and right walls of the case. The design of the rail bracket requires 2mm of space on either side of the case 26mm below the panel. This allows us to offer a 120hp (610mm) of space from wall to wall without a visible bracket while still offering the strength and stability of a metal bracket. Depending on the design of the module, the 2mm on either side of the case, 26mm below the panel could effect the placement of deeper modules which utilize the full width of the panel for their PCB and prevent their placement up against the side of the case without leaving a small gap.


Voltage Switch Settings